Guillermo Reyes, Sara Badia, Pablo Alvarez, Carlos Kallmeyer, Sonia Rodriguez, Anas Sarraj, Juan Bustamante Department of Cardiovascular Surgery, Hospital Universitario La Princesa, Madrid, Department of Cardiology, Hospital Universitario de Getafe, Madrid, Department of Cardiology, Hospital Universitario de Cuenca, Cuenca, Spain |
|
Background and aim of the study: The bileaflet Sorin Bicarbon Overline (Sorin Biomedica Cardio S.p.A., Saluggia, Italy) is a mechanical valve designed for total supra-annular implantation. However, the hemodynamics performance and early clinical outcome of the valve have not been well described. |
0.41 cm2, while the postoperative average EOA was 2.01 ± 0.26 cm2. No prosthesis-patient mismatch (PPM) was observed. The interventricular septum thickness (12.1 ± 2.6 mm versus 11.2 ± 2.0 mm; |
Results of Aortic Valve Replacement with the Supra-Annular Sorin Bicarbon Overline Prosthesis |
Click the above hyperlink to view the article, right click (Ctrl click on a Mac) to open in a new browser window or tab.
Please click the button below to purchase this article. Single article purchases are provided at $50.00 per article. Upon clicking the button below, single article user account subscription details are requested and, upon successful payment, a single article user account is created. Single articles are availble in your account for seven days after purchase.