You are here: Contents > 2017 > Volume 26 Number 1 January 2017 > CASE REPORTS > Transcatheter Valve-in-Valve Implantation: Failing Tricuspid Bioprosthesis in a Patient with Ebsteinís Anomaly

Transcatheter Valve-in-Valve Implantation: Failing Tricuspid Bioprosthesis in a Patient with Ebsteinís Anomaly

Pedro A. Villablanca1,6, Aman M. Shah1, David F. Briceno1, Ali N. Zaidi1,2,3, Mei Chau4, Mario J. Garcia1, David Slovut1,5, Cynthia Taub1

1Division of Cardiovascular Diseases, Montefiore Medical Center/Albert Einstein College of Medicine, New York, NY, USA
2The Children’s Heart Center, The Children’s Hospital at Montefiore/Albert Einstein College of Medicine, New York, NY, USA
3Montefiore Adult Congenital Heart Disease Program (MAtCH), Montefiore Heart and Vascular Care Institute, The Children’s Hospital at Montefiore/Albert Einstein College of Medicine, New York, NY, USA
4Department of Cardiovascular and Thoracic Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, New York, NY, USA
5Department of Cardiothoracic and Vascular Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, New York, NY, USA
6Electronic correspondence: pvillabl@montefiore.org; pedrovillablanca@hotmail.com

Transcatheter valve-in-valve (VIV) implantation has been recently proposed as an alternative to surgical reoperative aortic valve replacement in patients with a failing aortic bioprosthesis. Experience with transcatheter VIV implantation at other valve positions is very limited. Herein is reported the case of an 18-year-old man with Ebstein’s anomaly and severe tricuspid valve (TV) regurgitation status after bioprosthetic valve replacement, who developed new dyspnea on exertion three years after the initial valve replacement. Transesophageal echocardiography showed a severely dilated right atrium and new TV stenosis with an immobile leaflet. The patient underwent successful VIV implantation of a 29-mm SAPIEN XT bioprosthetic valve, with resolution of symptoms and no residual TV regurgitation or stenosis at the two-year follow up.


Video 1: Degenerative bioprosthetic tricuspid valve. TEE showing the degenerative bioprosthetic tricuspid valve, and color Doppler during systole showing severe tricuspid regurgitation.

Video 2: Degenerative bioprosthetic tricuspid valve. Three-dimensional TEE showing stenosis with an immobile leaflet creating a coaptation defect, viewed from the right atrium.

Video 3: Transcatheter VIV replacement with a 29-mm Edwards SAPIEN XT deployed within the tricuspid valve prosthesis. Final result after valve implantation, demonstrating a patent valve orifice, and appropriate apposition of transcatheter valve within a pre-existing surgical Carpentier-Edwards bioprosthetic valve, viewed from the right ventricle.

Video 4: Transcatheter VIV replacement with a 29-mm Edwards SAPIEN XT deployed within the tricuspid valve prosthesis. Final result after valve implantation, demonstrating a patent valve orifice, and appropriate apposition of transcatheter valve within a pre-existing surgical Carpentier-Edwards bioprosthetic valve, viewed from the right atrium.

The Journal of Heart Valve Disease 2017;26:114-117


Transcatheter Valve-in-Valve Implantation: Failing Tricuspid Bioprosthesis in a Patient with Ebstein’s Anomaly

Click the above hyperlink to view the article, right click (Ctrl click on a Mac) to open in a new browser window or tab.

Purchase this Article

Please click the button below to purchase this article. Single article purchases are provided at $50.00 per article. Upon clicking the button below, single article user account subscription details are requested and, upon successful payment, a single article user account is created. Single articles are availble in your account for seven days after purchase.