Sonometric Study of the Normal Tricuspid Valve Annulus in Sheep Matthew E. Hiro, Jerome Jouan, Matthew R. Pagel, Emmanuel Lansac,
Khee Hiang Lim, Hou-Sen Lim, Carlos M. G. Duran |
|||||||
Background and aim of the study: Mitral valve
dynamic changes during the cardiac cycle have been previously studied
in sheep using sonomicrometry. The study aim was to analyze geometric
changes of the normal tricuspid annulus in sheep using a similar methodology.
This is most likely the first tricuspid valve study using high temporal
resolution (200 Hz = 200 data points per second). |
expanded 28.6 ± 3.6% with similar maximum expansions
of each segment along the annulus: septal (10.4 ± 1.2%), anterior
(13.0 ± 1.5%), and posterior (14.0 ± 1.6%). The annulus
was saddle-shaped, with a circumferential expansion from elliptical at
minimum area to more circular at maximum area. The time delay to maximum
leaflet area and maximum papillary area occurred 83 ± 13 ms and
279 ± 30 ms respectively after maximum annulus area. |
||||||
|
|||||||