Prospective Study of Mitral Valve Repair with the CarboMedics AnnuloFlex™ Annuloplasty System: Effectiveness and Safety after One Year Vibhu R. Kshettry, Louis T. Kanda |
|||||||
Background and aim of the study: The CarboMedics
AnnuloFlex‘ annuloplasty system includes a flexible ring that may
be implanted as a complete or partial ring to correct mitral annular
dilatation by reinforcement of the entire annulus, or only the posterior
portion of the annulus. The study aim was to evaluate clinical and functional
results during the first year in patients receiving this flexible annuloplasty
system. |
obtained for 62 patients; cumulative follow up was 61
patient-years. One-year actuarial survival was 99%, freedom from thromboembolism
was 94%, from endocarditis 98%, and from reoperation 98%. Echocardiographic
evaluations performed at 3-6 months after repair (mean 4.7 months) showed
MR to be grade 0/1+ in 90% of patients and grade 2+ in 8%. Mitral valve
area was 3.4 ± 1.7 cm2, within normal limits (mitral valve area ≥1.5
cm2) in 95% of patients. Average peak and mean pressure gradients were
5.9 ± 3.0 and 2.8 ± 1.7 mmHg, respectively. Left ventricular
end-diastolic diameter decreased postoperatively, which may reflect successful
correction of MR after mitral valve repair. |
||||||
|
|||||||