Contents
Download PDF
pdf Download XML
237 Views
1 Downloads
Share this article
Research Article | Volume 18 Issue 1 (None, 2012) | Pages 1 - 11
Changes in mitral annular geometry after aortic valve replacement: a three-dimensional transesophageal echocardiographic study
1
Department of Anesthesia, Division of Cardiac Surgery, Beth Israel Deaconess Medical Center, Boston, MA 02115, USA
Under a Creative Commons license
Open Access
DOI : 10.61336
Published
Nov. 22, 2012
Abstract

Background and aim of the study: Intraoperative real-time three-dimensional transesophageal echocardiography (RT-3D TEE) was used to examine the geometric changes that occur in the mitral annulus immediately after aortic valve replacement (AVR).

Methods: A total of 35 patients undergoing elective surgical AVR under cardiopulmonary bypass was enrolled in the study. Intraoperative RT-3D TEE was used prospectively to acquire volumetric echocardiographic datasets immediately before and after AVR. The 3D echocardiographic data were analyzed offline using TomTec Mitral Valve Assessment software to assess changes in specific mitral annular geometric parameters.

Results: Datasets were successfully acquired and analyzed for all patients. A significant reduction was noted in the mitral annular area (-16.3%, p < 0.001), circumference (-8.9%, p < 0.001) and the anteroposterior (-6.3%, p = 0.019) and anterolateral-posteromedial (-10.5%, p < 0.001) diameters. A greater reduction was noted in the anterior annulus length compared to the posterior annulus length (10.5% versus 6.2%, p < 0.05) after AVR. No significant change was seen in the non-planarity angle, coaptation depth, and closure line length. During the period of data acquisition before and after AVR, no significant change was noted in the central venous pressure or left ventricular end-diastolic diameter.

Conclusion: The mitral annulus undergoes significant geometric changes immediately after AVR. Notably, a 16.3% reduction was observed in the mitral annular area. The anterior annulus underwent a greater reduction in length compared to the posterior annulus, which suggested the existence of a mechanical compression by the prosthetic valve.

Keywords
Recommended Articles
Research Article
Morphometric Analysis of the Human Mitral Valve: A Cadaveric Study
...
Published: 19/08/2025
Download PDF
Read Article
Research Article
Impact of Metformin Therapy on Serum Adiponectin Levels in Obese Individuals
Published: 14/08/2025
Download PDF
Read Article
Research Article
Prospective Study on Functional Outcome of CTEV By Ponseti Method of Cast Application
...
Published: 31/07/2025
Download PDF
Read Article
Research Article
To evaluate pelvic organ, prolapse by standardized pop q classification in preoperative and postoperative patients who are undergoing vaginal hysterectomy
...
Published: 31/07/2025
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease