Contents
Download PDF
pdf Download XML
468271 Views
95735 Downloads
Share this article
Research Article | Volume 16 Issue 1 (, 2010) | Pages 49 - 55
The Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement
 ,
 ,
1
Department of Cardiovascular Surgery, Charité-University Medicine Berlin, Germany. sven.beholz@charite.de
Under a Creative Commons license
PMID : -17315383
Published
Jan. 22, 2007
Abstract

Background and aim of the study: The new Freedom SOLO aortic valve, as a modification of the Pericarbon Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics.

Methods: In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacement (AVR) between 2001 and 2004. The Freedom SOLO valve was implanted in 30 patients using a supra-annular, subcoronary technique with one continuous subcoronary suture line (group FS). For comparison, the Pericarbon Freedom valve was implanted in 30 patients using an interrupted suture (group PFI), and in 30 patients using a continuous suture line at the inflow site (group PFC). Patient hemodynamics at discharge were investigated by monitoring echocardiographic peak and mean gradients, and regurgitation.

Results: The mean extracorporeal circulation time (75.5+/-22.7 min in FS; 83.7+/-21.0 min in PFC versus 110.9+/-31.4 min in PFI) and cross-clamp time (56.0+/-18.6 min in FS; 62.2+/-16.2 min in PFC versus 87.7 +/-25.4 min in PFI) were significantly shorter with the continuous implantation techniques. Hemodynamics were most favorable for the Freedom SOLO valve as compared to either implantation technique of the Pericarbon Freedom valve (mean gradient 7.4+/-4.6 mmHg in FS versus 10.6+/-6.0 mmHg in PFC and 11.0+/-5.7 mmHg in PFI). There were no paravalvular leakages or transvalvular regurgitations.

Conclusion: The Freedom SOLO stentless valve is easy to implant and demonstrates superior early postoperative hemodynamics. Due to the reduced cross-clamp time, it also offers an attractive option in isolated and combined AVR.

 

 

 

How to cite: Beholz, S., Dushe, S., & Konertz, W. (2007). The Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement. The Journal of heart valve disease, 16(1), 49–55.

Keywords
Recommended Articles
Research Article
Pure Tone Audiometric Profile of Patients with Type 2 Diabetes Mellitus and Its Association with Glycemic Status.
Published: 29/03/2016
Download PDF
Read Article
Research Article
A Prospective Study Of Outcome Of Functional Endoscopic Sinus Surgery In Chronic Rhino sinusitis.
Published: 31/07/2016
Download PDF
Read Article
Research Article
Problematic Smartphone Use, Sleep Quality and Behavioral Difficulties Among Adolescents: Associations and Independent Predictors
Published: 30/05/2026
Download PDF
Read Article
Research Article
Patterns and Prevalence of Problematic Smartphone Use Among School-Going Adolescents: An Analytical Cross-Sectional Study
Published: 30/05/2026
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease