Abstract

Background and aim of the study: The study aim was to investigate prosthesis-specific predictors for paravalvular aortic regurgitation (PAR) in self-expandable versus balloon-expandable transcatheter heart valves (THVs). PAR is frequently observed after transcatheter aortic valve replacement (TAVR). As self-expandable and balloon-expandable THVs engage differently with the native aortic valve structures, factors that impact PAR may differ between the prosthesis types.

Methods: A total of 137 TAVR patients who underwent pre-procedural multidetector computed tomography and post-procedural transthoracic echocardiography were studied. Predictors for PAR, including annulus area oversizing and aortic valve calcification mass and volume, were analyzed in a multivariate model.

Results: The Medtronic CoreValve (MCV) prosthesis was utilized in 68 patients (50%), and the Edwards SAPIEN (ES) prosthesis in 69 (50%). More than mild PAR was observed in 43 patients (32%). Among MCV patients, aortic valve calcification volume and mass were higher in those with more than mild PAR than in those with none or mild PAR (p = 0.04, p = 0.03, respectively). Among ES patients, the annulus area and perimeter oversizing were lower in those with more than mild PAR compared to those with no or mild PAR (p = 0.001). By univariate and multivariate logistic regression analysis, aortic valve calcification mass was the only independent predictor for PAR in MCV patients (p = 0.02), whereas in ES patients it was THV undersizing (p = 0.002), irrespective of the calcific burden.

Conclusion: For self-expandable THVs, aortic valve calcification mass was the strongest predictor of PAR, whereas for balloon-expandable THVs it was prosthesis undersizing. Hence, in patients evaluated for TAVR these parameters should guide the selection of prosthesis type.

 

 

 

How to cite: aStähli BE, Nguyen-Kim TD, Gebhard C, Erhart L, Frauenfelder T, Tanner FC, Falk V, Landmesser U, Nietlispach F, Lüscher TF, Maier W, Binder RK. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves. J Heart Valve Dis. 2015 Jan;24(1):10-21. PMID: 26182615.

 
Keywords
Recommended Articles
Research Article
Role of Metformin in Modulating Serum Ghrelin Levels in Obesity
Published: 30/12/2023
Download PDF
Read Article
Research Article
Morphometric Analysis of the Human Mitral Valve: A Cadaveric Study
...
Published: 19/08/2025
Download PDF
Read Article
Research Article
Impact of Metformin Therapy on Serum Adiponectin Levels in Obese Individuals
Published: 14/08/2025
Download PDF
Read Article
Research Article
Prospective Study on Functional Outcome of CTEV By Ponseti Method of Cast Application
...
Published: 31/07/2025
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease