Contents
Download PDF
pdf Download XML
500105 Views
30871 Downloads
Share this article
Review Article | Volume 5 Issue 1 (, 1999) | Pages 45 - 49
Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results
 ,
 ,
 ,
 ,
 ,
 ,
 ,
 ,
1
Department of Cardiovascular Surgery, National Cardiovascular Center, Osaka, Japan.
Under a Creative Commons license
PMID : 8834725
Published
Jan. 22, 1996
Abstract

Background and aim of the study: This report reviews our experience with single aortic and mitral valve replacement using the Carpentier-Edwards pericardial valve in a population younger than those of other reports.

Methods: Between 1984 and 1993, 106 patients underwent single aortic or mitral valve replacement using a Carpentier-Edwards pericardial valve. There were 49 aortic and 57 mitral implants. The mean age was 56.7 +/- 14.3 years. The follow up was 100% complete; total follow up being 273.3 patient-years in the aortic (AVR) and 348.0 patient-years in the mitral valve replacement (MVR) group, with a mean of 5.6 and 6.1 years, respectively.

Results: The rates of thromboembolic complications for AVR and MVR were 0.37% and 0.58% per patient year respectively. There were no cases of non-structural dysfunction or anticoagulant-related hemorrhage. The incidences of prosthetic valve endocarditis for AVR and MVR were 0% and 0.86% per patient year respectively. Structural deterioration (calcification and sclerosis) occurred in one patient after AVR and in six patients after MVR, all younger than 60 years of age. Freedom from structural deterioration at five years and 10 years was 100% and 92.9% +/- 6.9% for AVR, and 100% and 76.9% +/- 8.6% for MVR.

Conclusions: In conclusion, the Carpentier-Edwards aortic valve has a low incidence of valve-related complications at 10 years. Although late results of this valve in the mitral position were excellent in the elderly, leaflet degeneration is still a problem in patients under the age of 60 years.

 

 

 

How to cite: Murakami, T., Eishi, K., Nakano, S., Kobayashi, J., Sasako, Y., Isobe, F., Kosakai, Y., Kito, Y., & Kawashima, Y. (1996). Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results. The Journal of heart valve disease5(1), 45–49.

 
Keywords
Recommended Articles
Research Article
Role of Metformin in Modulating Serum Ghrelin Levels in Obesity
Published: 30/12/2023
Download PDF
Read Article
Research Article
Morphometric Analysis of the Human Mitral Valve: A Cadaveric Study
...
Published: 19/08/2025
Download PDF
Read Article
Research Article
Impact of Metformin Therapy on Serum Adiponectin Levels in Obese Individuals
Published: 14/08/2025
Download PDF
Read Article
Research Article
Prospective Study on Functional Outcome of CTEV By Ponseti Method of Cast Application
...
Published: 31/07/2025
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease