Review Article | volume 8 Issue 1 (, 2002) | Pages 85 - 95
A new flow model for Doppler ultrasound study of prosthetic heart valves
 ,
 ,
 ,
 ,
 ,
 ,
 ,
1
Laboratoire de génie biomédical, IRCM, Université de Montréal, Quebec, Canada.
Under a Creative Commons license
PMID : -10096489
Published
Jan. 12, 1999
Abstract

Background and aim of the study: Steady and pulsatile flow models used to assess the hydrodynamic aspects of prosthetic heart valves are generally made of Plexiglas and Lucite tubing. They often allow continuous-wave and pulsed-wave Doppler ultrasound velocity measurements to be made parallel to the flow, but cannot be used as such for ultrasound scanning of valve inflow and outflow velocities because of ultrasonic reverberation and refraction by the tubing. The aim of the study was to develop a new flow model which allowed ultrasonic scanning of the prosthetic valve flow for three-dimensional (3D) reconstruction of color Doppler flow distributions.

Methods: The flow model, designed with left ventricular and aortic chambers composed of agar gel which mimics the ultrasound characteristics of biological tissues, was developed and tested for comparative in vitro hydrodynamic and Doppler ultrasonic studies of aortic prosthetic valves. An electromagnetic flowmeter and a pressure monitor provided the flow and pressure signals for the hydrodynamic tests. The Doppler ultrasonic evaluation was performed with an Ultramark 9 HDI ultrasound system and a 3D ultrasound imaging system. The model was designed to enable assessment of prosthetic valve performance by pulsed-wave and continuous-wave Doppler velocity measurements, as well as by 3D color Doppler velocity measurements obtained by ultrasonic scanning of the left ventricle or aortic chamber with an ultrasound probe mounted on a motorized translation assembly.

Results: The study results showed that this new flow model can provide 3D color Doppler velocity distributions as well as accurate comparisons of hydrodynamic parameters of mechanical and bioprosthetic heart valves derived from Doppler and catheter measurements, both under steady and pulsatile flow conditions.

Conclusion: This new flow model can be used to evaluate the usefulness of hydrodynamic parameters for the assessment of prosthetic heart valves using both conventional Doppler echocardiography, as currently used in patients, and 3D color Doppler ultrasonic imaging.

 

 

 

How to cite: Durand, L. G., Garcia, D., Sakr, F., Sava, H., Cimon, R., Pibarot, P., Fenster, A., & Dumesnil, J. G. (1999). A new flow model for Doppler ultrasound study of prosthetic heart valves. The Journal of heart valve disease8(1), 85–95.

 
Keywords
Recommended Articles
Research Article
Role of Metformin in Modulating Serum Ghrelin Levels in Obesity
Published: 30/12/2023
Download PDF
Read Article
Research Article
Morphometric Analysis of the Human Mitral Valve: A Cadaveric Study
...
Published: 19/08/2025
Download PDF
Read Article
Research Article
Impact of Metformin Therapy on Serum Adiponectin Levels in Obese Individuals
Published: 14/08/2025
Download PDF
Read Article
Research Article
Prospective Study on Functional Outcome of CTEV By Ponseti Method of Cast Application
...
Published: 31/07/2025
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease