Fatigue analysis of clinical bioprosthetic heart valves manufactured using photooxidized bovine pericardium
 ,
1
School of Mechanical Engineering, The University of Leeds, UK.
Under a Creative Commons license
PMID : -10678391
Published
Jan. 11, 2000
Abstract

Background and aim of the study: Recent reports have given details of early clinical failures of bioprosthetic heart valves manufactured using dye-mediated photooxidized bovine pericardium. These failures were attributed to abrasion of the inflow surface of the leaflets against the cloth-covered inner face of the outer valve frame. These failures had not been detected during preclinical testing of such valves. The aim of this study was to determine if such failure modes could be replicated during fatigue testing of the photooxidized valves, and whether lining of the inflow face of the outer frame with pericardium could eliminate these failures.

Methods: The fatigue properties of six lined and six unlined PhotoFix(R) alpha valves was determined using two Rowan Ash fatigue testers which were cycled at 15 Hz for a maximum of 210 million cycles. The closing pressure within in each chamber was 110+/-10 mm Hg. Each valve was inspected every 40 million cycles for any signs of fatigue failure. All valves were tested to at least 210 million cycles.

Results: In all six lined PhotoFix alpha valves there was no evidence that wear, tear or abrasion of the inflow aspect of the leaflets adjacent to the inflow face of the outer frame had occurred. Only one unlined valve showed any signs of damage adjacent to the outer frame, as evidenced by loss of loose connective tissue, but this did not have the imprint of the cloth covering, which would have suggested actual wear. Effectively, after 200 million cycles, no fatigue failures of either the lined or the unlined PhotoFix alpha valves had occurred. Moreover, the leaflet tears that had been observed clinically were not replicated in this study.

Conclusion: Previous studies have shown a good qualitative, quantitative association between fatigue failure in Rowan Ash accelerated fatigue testers, and clinical experience in glutaraldehyde-treated bovine pericardial valves. The accelerated fatigue tester did not provide an adequate model for the prediction of clinical failure for the photooxidized pericardial valves.

 

 

 

How to cite: Butterfield, M., & Fisher, J. (2000). Fatigue analysis of clinical bioprosthetic heart valves manufactured using photooxidized bovine pericardium. The Journal of heart valve disease9(1), 161–167.

 
Keywords
Recommended Articles
Research Article
Morphometric Analysis of the Human Mitral Valve: A Cadaveric Study
...
Published: 19/08/2025
Download PDF
Read Article
Research Article
Role of Metformin in Modulating Serum Ghrelin Levels in Obesity
Published: 30/12/2023
Download PDF
Read Article
Research Article
Impact of Metformin Therapy on Serum Adiponectin Levels in Obese Individuals
Published: 14/08/2025
Download PDF
Read Article
Research Article
Prospective Study on Functional Outcome of CTEV By Ponseti Method of Cast Application
...
Published: 31/07/2025
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease